G3M Multi-parameter patient monitor
- FOB Price:Get Latest Price >
- Min.Order:1 Vial(s)
- Payment Terms:L/C
- Favorite
Business Type:Manufacturer
Country/Region:China
Ddu Verified
HOT Rank
8/10
General Meditech Inc.
We are professional supplier of Handheld Pulse Oximeter,Vital Signs Monitor,Multi-parameter Patient Monitor,Fetal/Maternal Monitor,Depth Of Anesthesia Monitor,ECG Series,Veterinary Monitor.
Business Type:Manufacturer
Country/Region:China
Ddu Verified
HOT Rank
8/10
The new model, 6 parameters of the 7 wave, 10.4 " color TFT-LCD display screen. Selection of NELLCOR oxygen plate or a digital oxygen plate. Resistance to weak pulse, anti motion interference, brightness adjustable volume unique. High-energy rechargeable battery.
1.Super ability in against electrosurgical interference. Neither in cutting nor in burning, ECG waveform and HR can be influenced, very short recovering time after defibrillation, especially suitable for use in emergency or operating room.
2.Unique thoracic impedance & nasal tube double model respiration test method (when patient can not lie quietly, only nasal tube respiration can detect the right respiration waveform and respiration rate).
3.10.4 color TFT LCD screen, High brightness,Wide viewing, 7 waveforms can be displayed on the same screen . lightness and volume are adjustable independently.
4.Streamlined outline design with sense of the times & foldable handle.
5. Multi-language interface selection: Chinese, English, Spanish, Portuguese, French, Arabic, Russian, Italian, Turkish, etc.
ECG
Heart rate(HR)
Measurement range: 30BPM ~ 300BPM;
Accuracy: 1 BPM or ±1 %.
Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10%
Noise level: ≤ 30μV
ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable
The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%
NIBPMeasurement range:
Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg
Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg
Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg
Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,
IBPMeasurement range: -1.3~40KPa(-10 ~ 300mmHg)
Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg
Unit display: kPa or mmHg( selectable)
Respiration RateMeasurement range: 0 BPM ~ 120 BPM;
Accuracy: ±1 BPM or ±5 %
TemperatureNumber of channels: 2
Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit
Measurement range: 25.0 ℃~ 45.0℃
Accuracy: ± 0.2 ℃
Response time: ≤ 3 min.
SpO2
Display type: Waveform, data
Measurement range: 0~100%
Resolution: 1 BPM
Pulse rate range: 30~250bpm
Accuracy: ±1bpm
Pulse RateMeasurement range: (30 ~ 250)bpm;
Accuracy: 1BPM
Trend review:Can Review history data of 360 hours